Role Simulations
Practical scenario-based assessments for CEC departments
0
Total Assigned
0
Completed
0
In Progress
—
Avg Score
Simulation Library — 9 Departments
A 132kV transmission line has tripped under heavy load conditions during peak hours, affecting three downstream substations supplying industrial clients. You are the senior T&D engineer on duty.
A 33/11kV substation transformer (TR-2, 20MVA) is showing abnormal readings: oil temperature at 95°C (alarm at 90°C), Buchholz relay has operated, and gas-in-oil analysis shows elevated hydrogen levels. You are the substation engineer.
During morning peak load, CEC's control room is managing a complex N-2 contingency: two critical transmission elements have failed simultaneously due to a severe storm. Frequency is dropping below nominal, and several protection relays are flagging.
CEC's SCADA system is showing anomalous behaviour: several RTU readings are displaying "stale" data, one HMI workstation is unresponsive, and the IT security team has flagged unusual network traffic on the OT (Operational Technology) network at 03:00 hrs.
CEC's Finance department has received a mid-year directive: reduce the capital expenditure budget by 15% (K45 million) due to a shortfall in electricity revenue from a major industrial client defaulting. You are the Senior Finance Manager.
CEC's transformer at Luanshya substation has failed catastrophically. A replacement 20MVA, 33/11kV transformer is urgently required. Simultaneously, an existing vendor is disputing a K8.2M contract for cable supply, alleging underpayment.
CEC's HR department is managing three simultaneous sensitive situations: (1) A senior electrical engineer has raised a formal grievance alleging racial discrimination in a promotion decision, (2) A Control Room supervisor has tested positive for alcohol during a random test, (3) Five engineers have resigned in the past month citing "better opportunities in South Africa".
CEC's Customer Service Manager must handle a major service crisis: a planned 4-hour maintenance outage extended to 19 hours due to unforeseen complications, affecting 8,500 residential and commercial customers in Kitwe's Parklands area. Social media is ablaze with complaints.
You are the General Manager of CEC's Network Operations division. You are simultaneously managing: (1) A major grid investment project 40% over budget and 6 months behind schedule, (2) A union strike threat by 600 field workers demanding 25% salary increases, (3) A Government directive to extend electricity to 5 rural communities by year-end.